Energy Consumption Monitoring Solution For Base Station

It is necessary to measure and monitor electrical parameters and measure energy in AC side of tower base station such as state grid,diesel,air conditioner,lighting,power supply and so on. In DC side,it is necessary to monitor electrical parameters and measure energy such as base station communication device,battery and other devices working under -48V power supply.The data can be real-time uploaded by RS485.

Structure

1.jpg

2.jpg

3.jpg

Main Functions

1. Measurement:multi circuits voltage,current,power,energy and other electrical parameters.
2. Communication:RS485 Modbus-RTU,NB or 4G
3. Certificate:With CE and IEC
4. Accuracy:0.5s or 1

Product Selection

Name

Picture

Model

Main Function

AC single circuit energy meter

1656666687139845.jpg

AMC96L-E4/KC

  1. Installation:panel mounted

  2. 1 circuit 3 phase input 220V/5A 50/60HZ

  3. Measurement:voltage,current,power,energy and other parameters.

  4. Communication:RS485 Mobus RTU

Multi circuits AC energy meter

1656666713835303.jpg

AMC96N-4E3

  1. Installation:panel mounted

  2. 4 circuits 3 phase or 12 circuits single phase AC input,external    CTs,50/60HZ

  3. Measurement:voltage,current,energy and other parameters.

  4. Communication:RS485 Mobus RTU

Multi circuits AC energy meter

1656666789156283.jpg

DTSD1352-xSyD

  1. Installation:DIN Rail 35mm

  2. X circuits 3 phase and Y circuits single phase AC input,external    CTs,50/60Hz

  3. Measurement:voltage,current,power,energy and other parameters

  4. Communication:RS485 Modbus RTU

Multi circuits DC energy meter

1656666963352529.jpg

AMC16-DETT

  1. Installation:DIN Rail 35mm

  2. 6 circuits DC input,-48V voltage input,current input by 5V output    hall effect current sensor

  3. Measurement:DC voltage,current,power,energy and other parameters

  4. With ±12V inner power supply for hall    effect current sensor

  5. Communication:RS485 Modbus RTU

Wireless energy meter

1656666835158466.jpg

ADW350

  1. Installation:DIN Rail 35mm

  2. 3 circuits DC input or 1 circuit 3 phase AC input

  3. Measurement:voltage,current,power,energy and other parameters

  4. Communication:NB or 4G

Hall Sensor

10.png

AHKC

  1. Ratio:1000A/5V

  2. Common Specification: 1000A/5V